Wuhan Corrtest Instruments Corp., Ltd.

Professional Focus Concentration

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Dual Channel Potentiostat Bipotentiostat /

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Contact Now
Wuhan Corrtest Instruments Corp., Ltd.
Visit Website
City:wuhan
Country/Region:china
Contact Person:Yushan Zhang
Contact Now

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Ask Latest Price
Video Channel
Brand Name :Corrtest
Model Number :CS2350M
Certification :CE, ISO9001
Place of Origin :Wuhan, China
MOQ :1set
Price :Negotiable
Payment Terms :T/T, D/P
Supply Ability :1000set/year
Delivery Time :5-10 working days
Packaging Details :standard Box
Name :EIS Bipotentiostat
Interface :Ethernet
Potential control range :Primary Channel: ±10V
second Channel :±10V
Current control range :±1A in each channel
Potential control accuracy :0.1%×full range±1mV
Current control accuracy :0.1%×full range
Potential resolution :10μV (>100Hz), 3μV (<10Hz)
Rise time :<1μS (<10mA), <10μS (<2A)
Current sensitivity :1pA
Reference electrode input impedance :1012Ω||20pF
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

EIS bipotentiostat CS2350M hydrogen permeation test has two sets of built-in independent potentiostat /galvanostat. The two channels can jointly complete experiment of RRDE and hydrogen permeation test. Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data. EIS bipotentiostat CS2350M hydrogen permeation test

is the real double-channel potentiostat. Experiments can also be conducted at the same time in each channel(see below picture: the 2 channels connect to 2 coin cells).It uses Ethernet connection. EIS module is included in both channels. Each set provides full electrochemical techniques including EIS.

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Applications of EIS bipotentiostat CS2350M

EIS bipotentiostat CS2350M can do all that a single-channel potentiostat can, as there are 2 sets potentiostat/galvanostat inside of CS2350M eis Bipotentiostat/Bigalvanostat. EIS bipotentiostat CS2350M can be used in the following applications, and can do testing on two samples at the same time.

(1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis

(2) Electrocatalysis such as Oxygen reduction reaction (ORR), OER, HER, CO2 reduction.
(3) Li-ion battery, solar cell, fuel cell, supercapacitor, advanced function materials, sensor, etc
(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.

One of the typical applications of EIS bipotentiostat CS2350M

Hydrogen permeation Test (HDT)

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Photo of EIS bipotentiostat CS2350M hydrogen permeation test setup

CS2350M bipotentiostat is combined with H-cells. By measuring current of cathode hydrogen charging and hydrogen atoms anode oxidation, it can further calculate the diffusion coefficient of hydrogen atoms in metal and hydrogen flux.

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation TestTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Hydrogen permeation test principle

The electrochemical method proposed by Devanathan-Stachurski to measure the diffusion rate of atomic hydrogen in metals.

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Diagram of EIS bipotentiostat CS2350M hydrogen permeation test

The device is composed of two electrolytic cells. The left one is hydrogen elimination chamber (anode chamber). A constant potential is applied on the anode surface of the specimen. The hydrogen atoms diffused from the cathode surface are oxidized on the anode surface.The right cell is the hydrogen charging chamber (cathode chamber). During hydrogen charging, the cathode current is applied on the cathode surface.

Specifications of EIS bipotentiostat CS2350M hydrogen permeation test

Specifications
Support 2-, 3- or 4-electrode system Interface: Ethernet
Potential control range: Primary Channel: ±10V second Channel: ±10V Current control range: ±1A in each channel
Potential control accuracy: 0.1%×full range±1mV Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz), 3μV (<10Hz) Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A) Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges Compliance voltage: ±21V
Maximum current output: ±1A in each channel CV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms SWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000s AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs Minimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHz Low-pass filters: Covering 8-decade
Potential and current range: Automatic Weight / Measurements: 6.5kg,36 x 30 x16cm
Operating System: Windows 7/8/10/11
Electrochemical Impedance Spectroscopy (EIS)
Signal generator
Frequency range:10μHz~1MHz AC amplitude:1mV~2500mV
DC Bias: -10~+10V Output impedance:50Ω
Waveform: sine wave, triangular wave and square wave Wave distortion:<1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time: minimum:10ms or the longest time of a cycle Maximum:106 cycles or 105s
Measurement delay:0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10V Current compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting

Techniques- EIS bipotentiostat CS2350M hydrogen permeation test

Bipotentiostat

  • Hydrogen permeation(Diffusion) Test (HDT)
  • Rotating Ring Disk Electrode(RRDE)
  • Faradaic efficiencyTest(FE)

Stable polarization

  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)

Transient Polarization

  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)

Chrono Method

  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)

Voltammetry

  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV)
  • Square Wave Voltammetry (SWV)
  • Differential Pulse Voltammetry (DPV)
  • Normal Pulse Voltammetry (NPV)#
  • Differential Normal Pulse Voltammetry (DNPV)
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)

Electrochemical Impedance Spectroscopy (EIS)

  • EIS vs Frequency (Nyquist, Bode)
  • Galvanostatic EIS
  • EIS vs Potential (IMPE)(Mott-Schottky)
  • EIS vs Time (IMPT)
  • Galvanostatic EIS vs Time

Corrosion Measurements

  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)

Battery test

  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging (PCD)
  • Potentiostatic Intermittent Titration Technique (PITT)
  • Galvanostatic Intermittent Titration Technique (GITT)

Amperometric

  • Differential Pulse Amperometry (DPA)
  • Double Differential Pulse Amperometry (DDPA)
  • Triple Pulse Amperometry (TPA)
  • Integrated Pulse Amperometric Detection (IPAD)

Stripping Voltammetry

  • Potentiostatic Stripping
  • Linear Stripping
  • Staircase Stripping
  • Square Wave Stripping
  • Differential Pulse Voltammetry Stripping
  • Normal Pulse Voltammetry Stripping
  • Differential Normal Pulse Voltammetry Stripping

Extensions

· Data Logger

· Electrochemical Stripping/ Deposition

· Bulk Eletrolysis with Coulometry (BE)

· Rs Measurement

Application

Corrosion: Corrtest potentiostats incl. EIS bipotentiostat CS2350M have all the electrochemical techniques for corrosion measurement such as OCP, polarization curve (potentiodynamic), EIS, Cyclic polarization CPP (passivation curve), Electrochemical Potentiokinetic Reactivation (EPR), Hydrogen diffusion test, ZRA, Electrochemical noise, etc. It can be used to study metal corrosion mechanism and corrosion resistance, and evaluate the coating durability and sacrificial anode current efficiency. It can also be used for rapid screening of corrosion inhibitors, fungicides, etc.

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation TestTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Left: Polarization curves of Ti-alloy& stainless steel in 3%NaCl solution Right: EN of low-carbon steel in 0.05mol/LCl+0.1mol/LNaHCO3

EIS bipotentiostat CS2350M uses correlation integral algorithm and dual-channel over- sampling technique, and has strong anti-interference ability. The internal resistance of the instrument is up to 1013Ω. It's suitable for EIS measurements of high-impedance system (such as coating, concrete etc)

Salt spray aging test of high impedance coating

Energy

With techniques LSV, CV, galvanostatic charge and discharge (GCD), Constant potential/ current EIS, and precise IR compensation circuit, Corrtest potentiostats incl. EIS bipotentiostat CS2350M are widely used in supercapacitor, Li-ion batteries, sodium-ion batteries, fuel cell, Li-S batteries, solar cell, solid-state batteries, flow batteries, metal-air batteries etc. It is an excellent scientific tool for researchers in the fields of energy and materials.

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation TestTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Salt spray aging test of high impedance coating CV curve of PPy supercapacitor in 0.5 mol/L H2SO4 solution

Electroanalysis

Corrtest potentiostat incl. EIS bipotentiostat CS2350M includes all the voltammetric methods such as NPV, DNPV, SWV, ACV, and can be used for fast analysis of the trace elements in the solution. Voltammetry stripping methods can do the Quantitative analysis according to the stripping peak current.

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

Stripping voltametric curves in solution of different Pb2+, Cd 2+,Zn2+ concentration

Electro-catalysisTwo Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

● Corrtest potentiostat incl. EIS bipotentiostat CS2350M can measure the half-wave potential (ORR), overpotential (HER, OER) of the catalyst, and has the function of peak power density and energy density calculation.

● Long-term cyclic measurement for ORR, OER, HER,

CO2RR by techniques such as cyclic voltammetry,

potentiostatic, galvanostatic. Faraday efficiency can be

measured with a bipotentiostat.

LSV curve of catalysts in alkaline solution

Two Channel EIS Bipotentiostat CS2350M For Hydrogen Permeation Test

● Maximum current can be 20A and compliance voltage can be 30V, and with IR compensation technique,

Corrtest potentiostat can precisely measure the overpotential of the electrode, which is a big advantage in electrocatalysis field.

Inquiry Cart 0